OSA 5225 Time Node
Selection by product category
Primary Reference Source (PRS) -- 6500B PRC -- 5585B PRS -- 3705 PHM
GPS Clocks & Timing -- 453x Series -- 5200B OEM Series -- 5230 GPS -- 5240 GPS -- 5581C GPS-SR -- 5230 GLONASS -- 5201 GLONASS
SSU / BITS - Synchronisation Supply Units -- 5548C SSU -- 5548C TSG -- 5548B SASE
SDU - Synchronisation Distribution Units -- 5533C SDU -- 5135 SDU -- 5530B SDU
E1/T1 Retiming Systems -- 5241 Retimer
OEM Solutions -- WiMAX series -- OSA 4500 OEM -- OSA 4501 GPS -- 5200B OEM Series -- OSA STAR Clock
Time & Frequency Systems -- 3700 PHM -- 4520 GPS-SP -- 4530 GPS-LN -- 5230 GPS-LN -- 5220 NTP Server -- 5225 Time Node -- 5020 LND -- 5030 PPS -- 5051/52 Dual Switch -- 5130 ANF -- F³ Equipment -- 2230 BVA FS
PTP - IEEE 1588 -- 5320 PTP Slave -- 5330 PTP Grandmaster
Testing & Measurement -- 5565 STS
Software & Management -- SyncView PLUS -- SyncView™ -- Local Manager -- RAM -- Sync Architect
GLONASS Clocks & Timing
Crystal Quartz Oscillators
Services
-- SyncSeminar
-- Factory Services
-- Support Services
-- Field Services
-- Training Courses
-- Network Consultancy
Selection by application
-- ATM Networks -- Base Stations -- Broadcasting -- Calibration Standards -- Computer Synchronisation -- DAB / DVB-T / DTV -- Digital Broadcasting -- DWDM Networks -- E-Business -- GLONASS -- IP-Based Networks -- Location Services / E911 -- Mobile Networks -- Network Synchronisation -- NTP Servers -- Optical Transport Networks -- Power Utilities -- Re-Timing -- Satellite Ground Stations -- SDH & SONET Networks -- Telephone Networks -- Time Distribution -- WiMAX
> OSA 5225 Time Node
HIGHLIGHTS
Dual synchronization inputs time centre
First input
Second input
IRIG-B / AFNOR NFS87500 1000Hz
IRIG-B / AFNOR NFS87500 DCLS
NTP (64 bits RSA Data Security, Inc. MD5 Message-Digest Algorithm)
Supervision and configuration through Ethernet (HTTP, SNMP, TELNET, “OSCILLOQUARTZ Network Manager” Windows® NT/XP/2000 based software)
19’’ 1U rack case (482x263x44mm)
Alphanumeric display
Redundant 18/72V DC power supply input
Manual and automatic compensation of the transmission delay
Standard outputs :
1 PPS (TTL)
SNMP, HTTP - Ethernet 10/100BaseT
Two static relay outputs for synchronization and power supply alarms
Up to 3 synchronization outputs :
IRIG-B / AFNOR NFS87500 1000Hz
IRIG-B / AFNOR NFS87500 DCLS
ASCII
PPS, PP2S, PPM, PPH (configurable pulses)
DCF
Additional NTP server
SMPTE
Low ageing OCXO accuracy
"Plug-and-play" installation
to the top
GENERAL INFO
The OSA 5225 Time Node is an accurate time centre, easily configurable with its outputs and dual synchronization inputs .
The OSA 5225 Time Node owns two configurable synchronization inputs for redundancy and several outputs. The time and date can be individually offset on each output.
to the top
Technical Information
Input/Output Flexibility
Dual external synchronization can be chosen on GPS, NTP, IRIG-B / AFNOR NFS 87500 1000 Hz or DCLS signals. Up to 3 synchronization outputs (IRIG-B, PPS, ASCII, 10MHz sine wave,…) all phase locked to the reference clock and individually configurable in offset and time zone.
Accuracy
Its own base time and its synchronization algorithm guarantee an output accuracy of up to 100 nanoseconds when GPS synchronized.
Security
High security level : 64 bits RSA MD5 encryption, leap time protection, high stability time base, SNMP alarm traps, static relay alarms, supervision with HTTP and front display.
Remote Management
Possible supervision with HTTP, SNMP, Telnet, alphanumeric display. Complete configuration and supervision with WEB page or “OSCILLOQUARTZ Network Manager” Windows® NT/XP/2000 based software. Firmware upgrade by Ethernet.
Internal Time Base
The OSA 5225 Time Node has autonomy to provide a stable output time code even when external synchronization is lost. In case of power supply failure, the
OSA 5225 Time Node can run normally for 2 hours on its internal battery.
Software
“OSCILLOQUARTZ Network Manager” Windows® NT/XP/2000 based software for supervision and configuration of all OSCILLOQUARTZ TIMING devices.
Some Applications
The OSA 5225 Time Node is important everywhere precise time is critic.
Autonomous, independent synchronisation of TCP/IP networks to UTC
Precise, UTC-traceable time stamping of e-business transactions
Precise time stamping of alarms, to reconstruct exact sequence of events
Synchronisation of telecom switches, for precise UTC-traceable billing
to the top
TECHNICAL SPECIFICATIONS
Environment & Dimensions
Power requirement
230 VAC
Max. : 0,1 A max.
Typ. : 20 mA plus 2mA per output
110 VAC
Max. : 0,2 A max.
Typ. : 40 mA plus 4mA per output
20-60 VDC Redundant Power Supply
Max. : 0,6-0,15 A max.
Environment
Operating temperature :
5 to 50°C (41 to 122°F)
Storage temperature :
-40 to 70°C (-40 to 151°F)
Electrical Autonomy
2 hours on internal NiMH battery, 5 to 7 years lifetime.
Dimensions
44mm (1U) x 263mm x 482mm (19”)
Weight
Certifications
CE, EN 60950, EN 55022, EN 50024
MTBF
Oscillator Stability
Synchronization input connectors
GPS (Antenna, preamp.)
Input Minimum signal level : 18dB
SMA + SMA to TNC adaptor
IRIG-B / AFNOR NFS 87500
1000 Hz * 2,2V p-p to 8 Vp-pp
2 points connector
IRIG-B / AFNOR NFS 87500
DCLS * (TTL, RS422)
2 points connector
Ethernet
(Manual and automatic compensation of the transmission delay)
GPS Antenna
Dimensions
3,05’’ D x 2,61’’ H
775mm x 662mm
Operating temperature
Cable
Standard Outputs
10 MHz sine wave
1 PPS
SNMP, HTTP - Ethernet 10/100BaseT
Two static relay alarms (Power Supply, Synchronization)
Optional Outputs (up to 3)
Signal
Connector
Accuracy
1 output - NTP - Ethernet 10/100BaseT
RJ-45
± 20µs (1)
4 outputs - IRIG-B / AFNOR NFS 87500 1000 Hz
(8,8V p-p)
8 pins
20µs (1000Hz)
4 outputs - ASCII RS422, RS485 (unidirectional)
1*DB9
500µs
4 outputs - ASCII RS232 (unidirectional)
1*DB9
500µs
4 outputs – IRIG B DCLS (TTL, differential TTL) or configurable pulse (PPS, DCF…)
8 pins
static relay (350V AC/DC, 130mA)
or phototransistor (70V AC/DC, 60mA)
3ms
100ns
differential TTL (rise time: 10ns)
100ns
NTP - Ethernet 10/100BaseT
RJ-45
± 20µs (1)
SMPTE
2 pins
(1) Equipment output interface.
Network Protocols
Network Time Protocol (NTP)
NTP v2 (RFC 1305), NTP v3 (RFC 1305), NTP v4*, SNTP (RFC 2030)
UDP / TCP Time Protocol (RFC 868)
SNMP v2c (RFC 1441)
MIB II (RFC 1213)
DHCP (RFC 2131)
HTTP / HTML
TELNET
Configuration
HTTP configuration.
« OSCILLOQUARTZ Network Manager » software for Windows® NT/XP/2000.
TELNET
Power
85-270 VAC, 47-63 Hz, 0.5A Max @ 120 VAC
3-pin IEC 320 on rear panel, 2 m. cord included
Size (HxWxD)
Chassis: 4.5 x 43.2 x 27.3 cm (1.75” x 17” x 10.75”)
Antenna: 6.7 x 7.8 cm diameter at base (2.61” x 3.05”)
NTP Client
* Contact Oscilloquartz for availability
to the top
Oscilloquartz
SA
Brévards 16
2002 Neuchâtel Switzerland
phone :
+4132 722 5555
fax
:
+4132 722 5556
-
legal notice
-