| Features |
| > |
19'' 2U high sub-rack format
|
| > |
Fully compliant to ITU-T G.811 / Stratum 1 when locked to GPS
|
| > |
Integrated high stability holdover functionality < 1 * 10-10 / day compliant ITU-T G812 type I, V, VI or Rubidium < 5 * 10-11/month compliant G.812 type 2
|
| > |
Up to 16 outputs individually configurable among 10MHz, 1PPS, 2.048MHz, E1
|
| > |
8 or 16 re-timing E1 / DS1 functionality
|
| > |
Time output NTP or IRIG-B
|
| > |
Roof or Wall / Windows antenna
|
| > |
Full local (RS232) / remote (TCP/IP) management interface and software |
|
| Benefits |
| > |
Synchronisation of cellular networks at BSC or MSC level
|
| > |
Re-timing of traffic singals affected by SDH/SONET pointer adjustements
|
| > |
Time and frequency reference for power utilities and public services
|
| > |
Specialised ATM and LAN/WAN applications
|
| > |
UTC traceable billing applications
|
| > |
Synchronisation of DVB-T transmitters in SFN (Single Frequency Networks)
|
| > |
Individually selectable user output |
|
| |
|
|
|
|
| Features |
| > |
ETSI or 19’’ sub-rack with dual Power converter and end-of-shelf alarms
|
| > |
Fully compliant to ITU-T G.811 / Stratum 1 locked to GPS
|
| > |
Single or Dual GPS for redundancy
|
| > |
High quality holdover < 2x10-10/day (OCXO)
|
| > |
Rubidium holdover capability < 5 x 10-11/month
|
| > |
Wide choice of output interfaces
|
| > |
Local / remote management interface and software
|
| > |
Optional NTP module for Stratum 1 NTP server (RFC 1305) or IRIG-B interface
|
| > |
External clock input signal filtering and processing
|
| > |
E1 and T1 re-timing functionality
|
| > |
certified NEBS level 3 |
|
| Benefits |
| > |
Compact multi function clock source
|
| > |
Economical G.811 frequency reference for Mobile, PDH, SDH, SONET networks
|
| > |
Full redundancy of critical functions
|
| > |
Optimum choice of internal clock performances
|
| > |
User outputs flexibility
|
| > |
Adaptable user configurations
|
| > |
Fully accessible for remote access
|
| > |
Plug in upgradeable timing functionality
|
| > |
Jitter filtering according to ITU-T G. 823
|
| > |
Multi channels traffic re-synchronisation |
|
| |
|
|
|
|
| Features |
| > |
Unique design for Master and Expansion shelves
|
| > |
From a few 10’s up to 1000’s of synchronisation outputs
|
| > |
Intuitive and modular architecture
|
| > |
Up to 200 protected (1:1) outputs in a 6U 19” or 12U ETSI shelf
|
| > |
Single System (Master and 4 Expansions) allows up to 1000 protected outputs
|
| > |
G.812 Type I or II or III SSU holdovers
|
| > |
Pass-through of input signal if failure or removal of both clock modules
|
| > |
Universal output & input card design
|
| > |
SSM on complete system (Master & Expansion)
|
| > |
Manageable with intuitive Local and Remote Graphical User Interface
|
| > |
Up to 80 re-timing channels
|
| > |
Optional NTP and IRIG-B output modules |
|
| Benefits |
| > |
Adapts to all telecom node sizes
|
| > |
Reliable synchronization, using the latest in hardware and software technologies
|
| > |
G.811 PRC redundant source with optional GPS cards
|
| > |
Scalability and reduced spare parts inventory
|
| > |
Accommodate overcrowded Telecom Hub Rooms and Switching Center rack spaces
|
| > |
Ensures absence of single points of failure and reliable uptime
|
| > |
Maximum flexibility with its wide choice of modular tile sets |
|
| |
|
|
|
|
| Features |
| > |
Unique design for Master, Expansion and Remote shelves
|
| > |
From a few 10’s up to 1000’s of Synchronization outputs
|
| > |
Intuitive and modular architecture
|
| > |
Digital indication of active input on the active clock module
|
| > |
Up to 200 DS1 or CC protected or unprotected outputs in a 6U shelf
|
| > |
Passthrough of input signal if failure or removal of both clock modules
|
| > |
Choice of Stratum 2 or Stratum 3E holdovers
|
| > |
Universal Input & Output card design
|
| > |
Available 20 pins output connector for compatibility with legacy wire-wrap panels
|
| > |
SSM on complete system (Master, Expansion, Remote)
|
| > |
TL1 manageable with Local and Remote intuitive Graphical User Interface
|
| > |
Up to 80 retiming channels
|
| > |
Optional NTP and IRIG-B output modules |
|
| Benefits |
| > |
Adapts to all telecom node sizes
|
| > |
Reliable synchronization, using the latest in hardware and software technologies
|
| > |
Stratum 1 redundant source with optional GPS cards
|
| > |
Scalability and reduced spare parts inventory
|
| > |
Accommodate overcrowded Telecom Hub Rooms and Switching Center rack spaces
|
| > |
Ensures absence of single points of failure and reliable uptime
|
| > |
Maximum flexibility with its wide choice of modular tile sets |
|
| |
|
|
|
|
| Features |
| > |
Stratum 1 NTP server
|
| > |
64 bits RSA Data Security, Inc. MD5 Message-Digest Algorithm
|
| > |
Supervision and configuration through Ethernet (HTTP, SNMP, TELNET)
|
| > |
19’’ 1U rack case
|
| > |
External GPS synchronization input
|
| > |
"Plug-and-play" installation |
|
| Benefits |
| > |
Compact, economic, fully manageable Stratum 1 NTP Server
|
| > |
Autonomous, independant synchronisation of TCP/IP network to UTC
|
| > |
Precise, UTC-traceable time stamping of e-business transactions
|
| > |
Precise time stamping of alarms
|
| > |
Synchronisation of telecom switched, for precise UTC-traceable billing |
|
| |
|
|
|
|
| Features |
| > |
Dual external synchronization can be chosen on GPS, NTP, IRIG-B / AFNOR NFS 87500 1000 Hz or DCLS signals
|
| > |
Up to 3 synchronization outputs (IRIG-B, PPS, ASCII, 10MHz sine wave,…)
|
| > |
19’’ 1U rack case
|
| > |
Alphanumeric display
|
| > |
Low ageing OCXO accuracy |
|
| Benefits |
| > |
Accuracy of up to 100 nanoseconds when GPS synchronized
|
| > |
Easily configurable with WEB page or “OSCILLOQUARTZ Network Manager”
|
| > |
The time and date can be individually offset on each output
|
| > |
High security level
|
| > |
Can run for 2 hours on its internal battery |
|
| |
|
|